BeckElec Frequency vs Temperature
 
Test date: 4/4/00  
             
P/N TC1-B5 ±1.5 ppm -20 to +70°C        
Freq. 10.0 MHz            
  Deviation in PPM
TEMP °C 1 2 3 4 5 6 7 8 9 10 Average
-40 -3.1 -2.8 -3.6 -2.6 -3.2 -3.4 -4.1 -1.0 -2.4 -2.8 -2.9
-30 -0.1 0.5 -0.1 1.2 0.5 -1.6 -0.5 1.5 0.7 0.5 0.3
-20 0.4 0.6 0.3 1.2 0.8 -0.1 0.1 1.2 0.6 0.5 0.6
0 -0.4 0.2 -0.1 0.7 0.5 -0.5 -0.4 0.4 -0.1 -0.1 0.0
25 -0.2 0.2 0.0 0.5 0.2 -0.1 -0.2 0.4 0.2 0.0 0.1
50 -0.5 0.0 -0.3 0.1 -0.8 0.0 -0.4 0.0 0.2 -0.3 -0.2
60 -0.6 0.3 -0.3 0.3 -1.2 0.0 -0.3 -0.1 0.2 -0.3 -0.2
70 -0.3 1.1 0.1 0.7 -1.2 0.7 0.4 0.3 0.8 0.2 0.3
75 0.1 1.8 0.7 1.3 -0.8 1.2 1.0 0.7 1.3 0.6 0.8
85 3.5 5.3 3.9 4.4 2.0 4.6 4.2 3.5 4.2 3.5 3.9